Service Information; Transport; Storage; Electrical Connection - Scheppach HM254SPX Traduccion Del Manual De Instrucciones Originales

Ocultar thumbs Ver también para HM254SPX:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 93

10.7 Service information

Please note that the following parts of this product are
subject to normal or natural wear and that the following
parts are therefore also required for use as consum-
ables.
Wear parts*: carbon brushes, saw blade, table insert
(art. no. 5901215010), saw dust bag
* Not necessarily included in the scope of delivery!
Spare parts and accessories can be obtained from our
service centre. To do this, scan the QR code on the
cover page.

11. Transport

• Tighten the handle (11) to lock the rotary table.
• Press the machine head (4) downwards and secure
with the locking bolt (23).
• Fix the saw's drag function with the locking screw for
drag guide (20) in rear position.
• Carry the equipment by the fixed saw table (15).
• When reassembling the equipment proceed as de-
scribed under section 8 and 9.

12. Storage

Store the device and its accessories in a dark, dry and
frost-proof place that is inaccessible to children. The
optimum storage temperature is between 5 and 30˚C.
Store the electrical tool in its original packaging.
Cover the electrical tool in order to protect it from dust
and moisture.
Store the operating manual with the electrical tool.

13. Electrical connection

The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions. The cus-
tomer's mains connection as well as the extension
cable used must also comply with these regula-
tions.
• The product meets the requirements of
EN 61000-3-11 and is subject to special connection
conditions. This means that use of the product at any
freely selectable connection point is not allowed.
• Given unfavourable conditions in the power supply
the product can cause the voltage to fluctuate tem-
porarily.
38 | GB
• The product is intended solely for use at connection
points where the following prerequisites apply:
a) A continuous current-carrying capacity of the
mains of at least 100 A per phase must be given.
• As the user, you are required to ensure that the
connection point at which you wish to operate the
product meets one of the two requirements, a) or b),
mentioned above. As necessary, consult your elec-
tric power company.
Important information
In the event of an overloading the motor will switch it-
self off. After a cool-down period (time varies) the mo-
tor can be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables of the same designation.
The printing of the type designation on the connection
cable is mandatory.
Connection type X
If the mains connection cable of this device is dam-
aged, it must be replaced by a special connection ca-
ble which can be obtained from the manufacturer or
its service department.
AC motor:
The mains voltage must be 220 - 240 V~.
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm
www.scheppach.com
.
2

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

5901222901

Tabla de contenido