bATTERy ChARGING
TIP:
· The generator DC rated voltage is 12V.
· Start the engine first, and then connect the generator to the battery for charging.
· Before starting to charge the battery, make sure that the DC protector is turned on.
1. Start the engine.
2. Connect the red battery charger lead to the positive (+) battery terminal.
3. Connect the black battery charger lead to the negative (-) battery terminal.
4. Turn the ESC "off" to start battery charging.
NOTICE
Be sure the ESC is turned off while charging the battery.
Be sure to connect the red battery charger lead to the positive (+)battery terminal ,and connect the black lead to the
negative (-) battery terminal. Do not reverse these positions.
Connect the battery charger leads to the battery terminals securely so that they are not disconnected due to engine
vibration or other disturbances.
Charge the battery in the correct procedure by following instructions in the owner's manual for the battery.
The DC protector turns off automatically if current above the rated flows during battery charging. To restart charging the
battery, turn the DC protector on by pressing its button to "ON". If the DC protector turns off again, top charging the battery
immediately and consult our company authorized dealer.
I
25