Entering The Welder Id Code; Connecting The Fitting; Reading The Fitting Code With A Handheld Scanner - HURNER HST 300 GeoTherm+ 2.0 Manual De Instrucciones

Ocultar thumbs Ver también para HST 300 GeoTherm+ 2.0:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
5.2

Entering the Welder ID Code

The welding unit can be configured to ask for the welder
identification code before the fitting code is entered. The
display screen then shows the message "Enter Welder
Code." (Later this screen can be accessed by a quick access
routine; see Sect. 6.1.) The numeric code can be entered
either by reading it from a tag with the scanner or by
pressing the ï, ð, ñ, ò cursor keys. Whether the welder
identification code has to be entered and if so, when or
how often, is determined in the "Settings" sub-menu of
the configuration menu (refer to Sect. 9.1).
When the welder code is read from a bar code using the
scanner, an audible signal confirms this and the screen
shows the read code and switches to the next input display.
When the code is entered manually, it is saved by press-
ing the START/SET key. If the code entered is not correct,
an "Input Error" message appears; check the sequence
of numbers and correct as needed. If the code entered is
correct, it is saved to system memory and inserted into the
welding reports to be printed.
Only an ISO standard-compliant welder identification code
is accepted by the unit. If the welder code feature is dis-
abled, the input screen for the welder code will not show.
5.3

Connecting the Fitting

Connect the connection terminals to the fitting and check
for proper contact. Use terminal adapters if needed. The
contact surfaces of the cable connection terminals or adapt-
ers and the fitting have to be clean. Dirty terminals may
lead to improper welding and also to overheated and fused
connection terminals. Protect the cable connectors against
getting dirty at all times. Terminals and push-on adapters
should be considered consumables and, therefore, have to
be checked before every welding operation and replaced
if damaged or dirty.
When the fitting is connected, instead of the "No Contact"
message (see Display 2) the number of the next welding
report appears, e.g., "Prot. No.: 0015."
5.4
Reading the Fitting Code with a Handheld
Scanner
Only the bar code on the tag sticking on the fitting to be
welded may be used. It is not acceptable to read the fitting
code tag of a fitting of a different kind if the intended
one is damaged or unreadable.
10
EN
HÜRNER HST 300 GeoTherm + 2.0 User's Manual
H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
*** Welder Code ****
++++++++++++++++++++
++++++++++
Start ?
Temp.: 20°C
DURA ‡
315mm
SAT
40.00V
Version September 2022
Display 3
90s
0.80Ω
Display 4