1. Set the ESC switch to "OFF" (1);
2. Set the air vent knob to "ON" position (2);
3. Set the 3 in 1switch to
▪ Ignition system on;
▪ Fuel circuit on;
▪ Air intake shut-off valves off.
You don't need air intake shut-off valves to start a hot
engine. Push the air intake shut-off valves knob to
the
"ON" position.
4. Pull the recoil starter slowly until it snaps into place, then
pull it quickly;
Hold the carrying handle (1A) firmly to prevent the
generator from falling off when pulling the recoil
starter.
5. After starting the engine, let it warm up until it does not
stop when the air vent knob returns to the
(4);
Remark:
▪ When starting the engine, with ESC switch turned on and
there is no charge in the generator:
▪ If you want to work with the Ecothrottle system, turn the
Ecothrottle switch to the "ON" position after the engine
warms up for 3 to 5 minutes.
▪ If room temperature is below 5°C, the engine will run at
the rated rpm (rotations per minute) for 5 minutes.
▪ If room temperature is above 5°C, the engine will run at
the rated rpm (rotations per minute) for 3 minutes.
▪ The ESC switch will operate normally after the above-
mentioned periods while it is on.
1. Switch off the ESC (1);
2. Disconnect any electrical device;
3. Turn switch 3 in 1 to
▪ Ignition system is off;
▪ Fuel circuit is off;
4. Turn the air vent knob to the "OFF" position (3) after the
engine cools down.
"CHOCKE" position (3);
"ON" position
"OFF" position (2):
The generator can provide emergency power to a residence
when there is an interruption in the power supply from the
public grid. When using the generator, the aim is not to
provide power for all the equipment in the house, but to
what is considered essential.
The connection of the generator to the electrical
wiring must be made in a correct way to avoid damage
to the generator and avoid the risk of accident.
Connections should only be made by a qualified electrician
or by persons with experience in electrical wiring. They
must ensure that the generator is isolated from the public
grid.
In the event of a public grid breakdown, whenever you
connect the generator to a building's electrical wiring to
supply power, you must turn off general electric circuit
breaker on the building's main switchboard.
Do not connect the generator to the electrical wiring of a
building if it does not have a general electric circuit breaker
installed by a qualified technician.
If the circuit breaker is not switched off, when the
public grid's power is restored, there may be returning
current in the generator and can cause:
▪ Electrocution to the user or others in contact with the
generator,
▪ Fire or explosion of the generator and fire in the
building's electrical wiring;
The generator cannot be connected to other power sources.
You must turn off the generator before connecting the
general electric circuit breaker in order to use public grid
power again.