PROBLEM
Runs in one direction only
Water leaking from base
Runs for short period of time
and/or stops, GFCI trips/won't
reset
Motor runs but shaft/brush does
not turn
No water through flexible shaft
Problem Not Listed
IRAM-EX-100 Manual 11/2017
PROBABLE CAUSE
•Leak in air control circuit
•Faulty wire connection(s)
•Leak in footswitch air
bellows or air hoses
•Faulty Air switch
•Leak in water circuit
plumbing
•Leak at shaft manifold seal
•Electrical short to ground
•Overheated, disconnect
from power. Unit will
automatically turn on when
cool.
•Problem drive coupler
•Broken flexible shaft
•Problem with water supply
•Inlet screen clogged
•Solenoid valve not
functioning
Call Goodway Customer Service: 1-800-370-2855
7
REMEDY
• Disconnect power. Disconnect air
hoses from air switches to allow
foot pedal bellows to inflate to full
height. Reconnect and tighten all
connections
•Disconnect power. Check Wiring.
•Switch air hoses to isolate
problem (machine or footswitch)
•Check/replace air switches
•Disconnect power. Check hoses
and fittings for leaks. Tighten
loose connections.
•Check for leak where drive shaft
enters shaft manifold. Replace
manifold seal.
•If GFCI trips often call Goodway.
There may be an unsafe
electrical condition.
•Allow unit to cool.
•Disconnect power. Check drive
coupler for damage
•Replace shaft fittings and/or core.
•Water supply not on, restrictions
in hose or hose too small, water
supply pressure insufficient.
•Remove hose and clean screen.
•Replace solenoid valve, call
Goodway