BLUEHELIX HITECH RRT K 50
Index Description
b20 Flue material selection
b21 Not implemented
b22 Not implemented
Standard flue shutdown
b23
maximum temperature
PVC flue shutdown maxi-
b24
mum temperature
CPVC flue shutdown maxi-
b25
mum temperature
b26 Not implemented
Calibration procedure [
b27
]
SETUP
b28 Not implemented
b29 Restore Factory Values
P30 Heating ramp
P31 Heating standby time
P32 Heating Post-Circulation
P33 Pump operation
P34 Pump modulation DeltaT
Modulating pump min.
P35
speed
Modulating pump start
P36
speed
Modulating pump max.
P37
speed
Pump deactivation tempe-
rature during Post-Circula-
P38
tion
Pump activation hysteresis
temperature during Post-
P39
Circulation
P40 Heating user max. setpoint 20 ÷ 90°C
P41 Max. output in heating
Anti-Legionella function fre-
P42
quency
P43 Hot water tank hysteresis
Hot water tank preparation
P44
flow
P45 DHW standby time
P46 DHW user max. setpoint
DHW pump Post-Circula-
P47
tion
P48 Max. output in DHW
P49 Not implemented
P50 Not implemented
EN
Range
0 = Standard
1 = PVC
2 = CPVC
--
--
60-110°C
60-110°C
60-110°C
--
5 = Calibration procedure [
All other values = Calibration procedure [
AUTO
bled
(See
"Calibration procedure [AUTO SETUP]" on page 303
--
See
*** '* Restore Factory Values' on page 308 ***
10÷80
(ex. 10=20°C/min, 20=12°C/min, 40=6°C/min, 80=3°C/min)
0-10 minutes
0 ÷ 255
(Multiply the value by 10. Example 15 x 10 = 150 seconds)
0 = Continuous pump (active only in winter mode)
1 = Modulating pump
0 ÷ 40°C
30 ÷ 100%
90 ÷ 100%
90 ÷ 100%
0 ÷ 100°C
0 ÷ 100°C
0 ÷ 100%
0 = OFF
1÷7 = Days
0 ÷ 80°C
0 ÷ 100°C
30 ÷ 255 seconds
40 ÷ 70°C
0 ÷ 255 seconds
0 ÷ 100%
--
--
cod. 3541Z782 — Rev 00 - 10/2022
] enabled
AUTO SETUP
AUTO SETUP
)
.
Default
0
--
--
105
93
98
--
] disa-
0
--
0
40
4
15
1
20
30
90
100
55
25
80
= 85
28 kW
= 90
34 kW
0
2
80
120
65
30
= 100
28 kW
= 100
34 kW
--
--
307