Lincoln Electric VIKING 2450ADV Serie Manual Del Usuario página 15

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Delay Control
This control is designed to protect the welder's eyes from the strong residual rays
after welding. Changing the delay settings will vary the dark to light time between
0.1 seconds (LOW) and 1.0 seconds (HIGH). Press the MODE button to select
Weld or Cut Mode. Press the DELAY button to select Delay Control Mode. Press
the DELAY button to select the desired sensitivity level displayed on the LED
scale. The scale will illuminate orange for Delay Control Mode. There are 5
increments of delay control. The HIGH setting is recommended for high amperage
applications where the weld puddle is still very bright after the welding arc has
ceased and for situations where the filter may be temporarily blocked from seeing
the welding arc.
Power
This ADF is powered by a replaceable battery and solar power. The battery is
located at the top corner of the ADF cartridge. Replace the battery when the LOW
BATTERY light is lit. See the specification chart on page 3 for the type of battery
required.
9

Publicidad

Tabla de contenido
loading

Tabla de contenido