WIRING

W A R N I N G
s
WARNING
!
codes before installation. The installation must be in accordance with
their regulations as well as the most recent National Electrical
Code (NEC).
Check the pump label for proper voltage required. Do not connect to
voltage other than that shown.
A ground fault circuit interrupter (GFCI) is required.
The pump should be connected or wired to its own circuit, with no
other outlets or equipment in the circuit line. The fuses and circuit
breaker should be of ample capacity in the electrical circuit.
See table below:
Pump
HP
LG-SS100V
1
s
WARNING
!
mounted to the pump must not be modified in any way, with the
exception of shortening the cord to fit into a control panel. Any splice
between the pump and the control panel must be made within a
junction box mounted outside of the basin and comply with the
National Electrical Code. Employ a licensed electrician.
s
WARNING
!
Do not use the power cord for lifting the pump.
6
W A R N I N G
Check local electrical and building
Votage
Breaker Amps
115
15
The flexible jacketed cord assembly

SPECIFICATIONS

Discharge Size
Intake Size
Pump Housing
Volute
Impeller
Single-phase permanent split capacitor with automatic reset
Motor
Hardware
Bearings
Pump Shaft Seal
Stationary carbon with Nitrile boot and rotating ceramic seat
Power Cord
18 AWG 3-conductor, copper, stranded, 10' length
The motor housing contains oil to cool the motor and to
lubricate bearings and seals. These pumps are capable of
operating with the motor housing partially exposed for
Cooling
extended periods, providing sufficient motor cooling and
bearing lubrication. However, for the best cooling and
longest motor life, the liquid level being pumped should
normally be above the top of the cast iron motor housing.
Electrical Diagrams
Plug
Vertical Switch with
Piggyback Plug
115 V Plug
A-N613
1-1/2" FNPT
3/4" opening
300 Series Stainless Steel
Cast Iron
Cast Iron
thermal overload protection
Stainless steel
Ball, top and bottom
Receptacle
Cap
M
Ground
Pump