INSTALLATION
s
WARNING
!
codes before installation. The installation must be in accordance with
their regulations as well as the most recent National Electrical
Code (NEC).
1.
Pump must be installed in a suitable gas-tight basin that is at
least 18" in diameter and 24" deep and vented in accordance with
local plumbing codes. (Note: An 18" x 22" deep perforated basin
can be used if in accordance to all applicable plumbing codes.)
2. Clean any debris from the basin and set the pump in the center
of the basin (see "Typical Installation"). A solid bottom will
prevent clogging of the pump from sand and dirt.
3. The pump must be placed on a hard, level surface. Never place
the pump directly on clay, earth or gravel surfaces. These
surfaces contain small stones, gravel, sand, etc. that may clog or
damage the pump and cause pump failure.
4. Do not attempt to restrict the intake side of these pumps.
Restricting the intake may cause damage to the seal and may
starve the pump. If you require reduced flow rates, place a valve
on the discharge side of the pump. Or, if flexible vinyl tubing is
used, a clamp can be used on the tubing to restrict the flow.
5. Connect discharge piping. Use pipe joint compound at all
connections. The discharge pipe should be as short as possible
and contain as few elbows as possible. The discharge pipe should
be the same diameter as the discharge size to reduce pipe
friction losses. A smaller pipe will restrict capacity and reduce
pump performance. The sump pump comes with a 1-1/2" female
pipe thread discharge.
a. Support the pump and piping while assembling and when
installed. Failure to do so may cause the piping to break, the
pump to fail, motor bearing failures, etc.
b. Always install a union in the discharge line just above the
basin cover to allow for easy removal of the pump for
cleaning or repair.
4
Check local electrical and building
6. A check valve must be used in the discharge line to prevent
backflow of liquid into the basin. The check valve should be a
free-flow valve that will easily pass solids.
s
CAUTION
!
a.
the check valve when handling solids, install it in a
horizontal position or at an angle of no more than 45°. Do
not install the check valve in a vertical position, as solids
may settle in the valve and prevent the valve from opening
on start-up.
b. When a check valve is used, drill a relief hole (1/8" or 3/16"
in diameter) in the discharge pipe. This hole should be located
below the floor line between the pump discharge and the
check valve. Unless such a relief hole is provided, the pump
could "air lock" and will not pump water even though it
will run.
7.
Tape the pump and switch cords to the discharge line with
electrical tape. This will protect the cord from damage.
8. Test the operation of the pump system by following the
instructions in the "System Operation Testing" section of this
manual. Do not attempt to operate the pump without water;
this will damage the seals and bearings and could result in
permanent damage to the pump.
9. Place cover over basin. This cover will help prevent debris from
entering the pit and will guard against accidental injury.
s
WARNING
!
power before touching the pump or discharge when water is present
in the basin. Failure to do so can result in hazardous electrical shock.
For best performance of
Always disconnect the electrical