5.7 MANUAL ACTIVATION OF THE LOAD SYSTEM
In case of 昀椀rst use (pellet tank initially empty) or to test operation of the load unit, manual activation of loading
is possible.
On the control panel of the stove:
a) Using the arrow keys
b) Select password "7" with the key
c) Scroll with the key
d) Select password "54" with the key
e) Holding the key
f) Releasing the key will end the load operation.
Attention!
• This function is only active when the stove is o昀昀 and cold.
• Before switching on again, ensure that there are no pellets in the grate.
26
navigate to the set-up menu
and con昀椀rm with the key
and select sub-menu
and con昀椀rm with the key
the load system will activate and the display will show the incremental bars
004776500 - 11/12/2019
and press the key
;
[3 1 ]
;
;
;