• Open the front panel.
• Remove the cover as shown in the picture (removing a screw).
• For electrical connections, refer to the circuit diagram on the right side of the unit
below the front panel.
• Connect the wires to the screw terminals following the numbering. Use the
proper cable size for power input (see nameplate on unit) and in accordance with
all applicable national safety codes.
The cable connecting the outdoor and indoor units must be suitable for
outdoor use.
The plug must be accessible once the appliance has been installed.
Efficient grounding must be ensured.
If the power cord is damaged, it must be replaced by an authorized service
center.
Note: Optionally, the cables can be connected to the main PCB of the indoor unit
depending on the model purchased.
Gas pipe connection
The pipe can be installed in 3 different
directions, as shown in the drawings below.
When the pipe is installed in position 1 or 3,
make a cut with cutex.
Install the pipe in the direction of the hole in
the wall and tape the copper pipes, drain
pipe and electrical wires together so that
water can flow freely.
Do not remove the pipe cap until it is
connected, to prevent dirt or moisture from
entering the pipe.
Do not bend the pipe too far and try to
extend or stretch it as shown in the pictures.