Information for the installer
Tube length with standard load
Max. distance between indoor and outdoor unit
Additional Gas Charge (Starts at 5m)
Max. level difference between indoor and outdoor
unit
Type of gas
Tightening screws
Pipe
"¼" (ø 6)
3/8" (ø 9.52)
"½" (ø 12)
5/8" (ø 15.88)
Wiring diagram
For different models, the wiring diagram may be different. Refer to the wiring diagrams
glued to the unit on the inside and outside of the unit, respectively.
In the indoor unit, the wiring diagram is glued under the front panel;
On the outdoor unit, the wiring diagram is glued to the back of the outer handle cover.
MODEL
Tightening
screw (N x m)
15-20
31-35
35-45
75-80
Corresponding
pressure
Wrist strength
Arm strength
Arm strength
Arm strength
9k/12k
5 m
25 m
15 g/m
10 m
R32
Port Nut
Protective
covers
18k/24k
5 m
25 m
25 g/m
10 m
R32
Tightening bolt
( N x m)
7-9
25-30
64