INSUFFICIENT VACUUM SIGNAL

FVSD 2900 has a device that detects the level of vacuum reached inside the chamber and which is
determinant for the correct functioning of the appliance. If a minimum vacuum level is not reached,
the cycle is automatically interrupted after about one minute. The appliance indicates the anomaly
using the luminous indicator of the
nied by an intermittent acoustic signal.
The signal re-enters on the activation of a new cycle. If the cause is not removed, the alarm situation
described is repeated.
If an insufficient vacuum is signalled, before calling the Dealer or the authorised after-sales centre,
check the correct closure of the lid and the correct insertion if the gasket in the seat.
If, after the controls suggested, the anomalous situation remains, call the Dealer or authorised after-
sales, communicating the information on the plate data.
AtteNtIoN! Do not try to repair or modify any part of the appliance: as well as making
the warrant null and void, it can be potentially dangerous. entrust specialised techni-
cians only.

TEMPORARY INTERRUPTION OF ThE ELECTRIC POWER SUPPLY

If a power cut occurs during a functioning cycle, on restore of the power supply, the vacuum chamber
is decompressed and the machine goes back to initial switch-on conditions.
If the power supply is cut-off in Initial switch-on phase, once the power supply is restored the machine
goes back to Initial switch-on.
AtteNtIoN: In the event of a power outage during the vacuuming process, the vacu-
um state is maintained in the chamber and the lid cannot be opened. Never attempt to
open the lid by force or with the use of tools. once electrical power is restored it will
again be possible to open the lid.