Following functions can be set via the Steinel
Connect app:
– Time setting 5 s - 60 min
– Twilight setting 2-1,000 lux, daytime mode,
lux teach, time teach
– Reach adjustment
– Bluetooth interconnection
LED function
– Initialisation: LED flashes green.
– Bluetooth identification: LED slowly flashes blue.
– Normal mode: LED is OFF.
Time setting
The time you want the sensor switch controlled
light to stay ON for can be set to any period from
approx. 5 seconds to a maximum of 60 minutes.
Any movement detected before this time elapses
will restart the timer.
Note:
After the load switches OFF, it takes approx. 1 sec-
ond before movement can be detected again. The
load will only switch light ON again in response to
movement once this period has elapsed.
Twilight setting
The response threshold chosen for the sensor
switch can be infinitely varied from approx. 2 to
1,000 lux.
Setting detection zone
The area covered by the sensor can be divided
into three zones (Fig. 6.1):
– Each of the three zones can be activated or
deactivated separately.
– Reach can be set for each of the three zones.
Note:
It is recommended to select the shortest time for
setting the detection zone.
Note:
The twilight setting control must be set to daylight
mode when adjusting the detection zone and
performing the functional test in daylight.
Bluetooth interconnection (Bluetooth mesh)
The sensor switch does comply with the Bluetooth
mesh standard. It can be interconnected with
all products complying with the Bluetooth mesh
standard.
The sensor switch is configured by Steinel Connect
app. Appropriate network keys are saved on the
smartphone or tablet the first time a connection is
made between sensor switch and Steinel Connect
app. The key rules out any unauthorised access to
the sensor.
The network key must be shared for access via
another smartphone or tablet.
7. Cleaning and Maintenance
Hazard from electrical power.
Contact between water and live parts can result in
electrical shock, burns or death.
• Only clean tool in a dry state.
Risk of damage to property!
Using the wrong detergent can damage the light.
• Clean sensor switch with a moist cloth without
detergent.
8. Troubleshooting
Unit without power.
– Fuse not switched ON or faulty.
• Switch ON fuse.
• Change faulty fuse.
– Break in wiring.
• Switch ON mains switch.
• Check wiring with voltage tester.
– Short circuit in mains power supply lead.
• Check connections.
Unit does not switch ON.
– Wrong twilight setting selected.
• Re-set brightness response threshold
– Mains switch OFF.
• Switch ON mains switch.
– Fuse not switched ON or faulty.
• Switch ON fuse.
• Change faulty fuse.
– Detection zone too small or incorrect.
• Check and adjust detection zone.
– 12 –