Machine speed
OLIVATOR E 5000 can be set up by the user for constant speed operation or allows the choice
between 3 di erent speeds. The default setting is constant speed mode.
Speed setting E5000 L - E5000 XL
Speed setting E5000 BPL - E5000 BPXL
To change the speed con guration,
proceed as follows:
Press and hold the button on the
handle, then connect the clamps to the
battery.
The two LEDs on the handle start ashing
simultaneously. After 10 seconds, the
frequency of the ashing decreases. This
means that the program has stored the new
working set up. At this point, disconnect the
power supply. The next time the machine is
switched on, each time the button is
pressed, a speed variation will correspond.
To return to the previous mode, repeat the
procedure.
To change the speed con guration,
proceed as follows:
Press and hold the button on the
handle, then turn the battery on.
The two LEDs on the handle start ashing
simultaneously. After 10 seconds, the
frequency of the ashing decreases. This
means that the program has stored the new
working set up. At this point, disconnect the
power supply. The next time the machine is
switched on, each time the button is
pressed, a speed variation will correspond.
To return to the previous mode, repeat the
procedure.
30