REF. 52841
When finished working with the tool, disconnect air hose and press again the trigger to release
any remaining air pressure in the air chamber of the tool.
5. MAINTENANCE INSTRUCTIONS
Before disconnecting the air hose, make sure hose ends are well cleaned.
After each use, clean the tool with a cloth and store it in the box.
Clean tools that have not been used in the past 6 months and oil them adequately
6. TROUBLESHOOTING
PROBLEM
Air gun without enough
power
Air gun emits moisture
Noise level increases
POSSIBLE CAUSE
Lack of air pressure
Lack of lubrication
Air hose leaks
Worn rotor blade
Worn ball bearing in motor
There is grit in the tool
Water may be present inside the
air compressor tank
Water may be present inside the
air hose
Lack of lubrication
· 5 ·
SOLUTION
Check air pressure in gauge
Lubricate tool's air intake
Seal the leaks
Replace rotor blade
Replace, clean or grease ball
bearing
Flush the tool with air tool oil
Drain out the water of the compres-
sor tank
Drain out the water of the air hose
Increase dripping speed in the
lubricator
600ml
600ml
100ml
100ml