i
CAUTION Risk of damage to the bat-
teries
Never expose the battery to direct sun-

light for prolonged periods of time.
Only store the battery in the temperature range of

0°C to 45°C
Occasionally clean the ventilation slots of the bat-

tery with a clean, dry cloth
Protect the battery against moisture and water

Store the batteries far away from metal objects

such as screws, nails etc

Checking the battery charge

Refer to figure {F} on page IV:
The three LEDs (16) of the charge level indicator
symbolize the charging condition of the battery. The
charging condition can only be checked when the
dispenser is switched off, but also when the battery is
not fitted.
• Press button (17) to check the charge
LED status
3 LEDs light up constantly
2 LEDs light up constantly
1 LED lights up constantly
1 LED flashes
If none of the three LEDs lights up, the battery
must be replaced.
Instruction handbook ElectraFlow
Dual Ultra · Version 1.3 · 9.4.21
Charging condition
>= 2/3
>= 1/3
< 1/3
Reserve
7 of 12

Inserting/removing the battery

Refer to figure {A} on page III:
1. Place the charged battery into the base of the
dispenser from the front and push the battery into
the base until it engages
When inserting/removing the battery it is
recommended to lock the trigger (1) by
engaging trigger lock (12).
2. To release the battery press the release button (10)
and pull the battery out of the dispenser. Do not use
excessive force.

Changing the straps (MR only)

Refer to figure {G} on page IV:
1. Press top/ bottom of strap to unclip from frame
2. Press two side clips to fully remove them from frame

Removing the plungers (MR only)

Refer to figure {H} on page IV:
1. Using a 13 mm spanner loosen the rack back nut
2. Unscrew the plunger from the rack by hand
3. To replace plunger repeat steps 2 and 1
Cartridge
Right Hand
Ratio
Plunger (X)
1:1
2:1
4:1
10:1
Y
X
Left Hand
Plunger (Y)
A
A
B
C
B
D
E
F