Reading the Last 100 Opening and Closing Records of the Safe
Note: In the case of no batteries or insufficient battery power, the mechanical key
openings/closings cannot be recorded.
To check the last 100 opening/closing records, the door must be opened (that is, the bolts are
retracted).
Press "CLEAR" button twice, the display shows "PROG", enter "060516" and then press the
"LOCK" button. Each record will be displayed in 3 screens:
The first screen will show:
1.
The record number,
2.
If the safe was opened or closed
3.
The opening method
The second screen will show: The Date
The third screen will show: The Time
First Screen:
0
0
6
(first 3 digits of the screen) indicate the Record Number (where record 001 is the last
opening/closing of the safe);
th
(the 4
digit of the screen) indicates the action of the door
"O" means Safe was opened
"C" means Safe was closed
(the last two digits of the screen) indicate the opening/closing method of the safe
"01" means - by user's code;
"02" means - by master code;
"03" means – by CEU (if applicable)
"09" means – by override key
Second Screen:
Displays the Date that the safe was opened/Closed, in this case February 12
1
2
0
Third Screen:
Displays the Time that the safe was opened/Closed, in this case at 16:09:32
1
6
0
Navigation Instructions:
Press "2" to go back one record
Press "8" to go to the next record
Press "4" to show the previous content on the screen (Screen 1, Screen 2, Screen 3 of the same
record)
Press "6" to show the next content on the screen (Screen1, Screen 2, Screen 3 of the same record)
Press "5" to go to the latest opening/closing record
Press "CLEAR" to end this operation
O
0
1
2
1
9
9
3
2
th