Menu 5 Various settings
Menu
Entry
Selection
item
50
Key switch function (J7)
0
Pulse input OPEN/CLOSE (default setting)
1
Inhibit control panel
2
Inhibit external control elements
3
Inhibit control panel and external control
elements
4
Activate control elements for 10 seconds
5
Switch-over to dead man mode for closing
6
Switch-over to 1/2 opening (winter mode)
7
Pulse input OPEN-STOP-CLOSE
8
Pulse input 1/2 OPEN-STOP-CLOSE
9
Pulse input for smoke and heat extraction
system (setting in menu item 55)
10
Activate control elements for 300 seconds
11
Input for electrical interlocking EDL100
51
Function of external control devices
0
Three-button-control (default setting)
1
Open-Stop-Close function (J1.3 1/2, J1.4 full
opening)
52
001-256 Entry of control address
53
Door control module and inflatable door sealing
0
Off (default setting)
1, 2, 3, 4 For control profiles see control door module
5
RadioBand module, wireless closing edge
(optional)
6
Reserved
54
Extended control
0
Off (default setting)
1, 2, 3 For control profiles see extended control
55
Door setting for smoke and heat extraction
system position
59
18
Do not change control variant!
- -
Exit menu
Menu 6 Radio
Menu
Entry
Selection
item
60
Programming the start button on the hand-held
transmitter
61
Programming the 1/2 opening button on the hand-
held transmitter
62
Programming the light button on the hand-held
transmitter
63
Deleting radio codes
Press for 5 s
- -
Exit menu
Menu 7 DU settings
Menu
Entry
Selection
item
71
Opening speed
20 - 65 Speed in revolutions / min.
30
Factory settings
72
Closing speed
20 - 30 Speed in revolutions / min.
20
Factory settings
73
Increased closing speed
20 - 30 Speed in revolutions / min.
20
Factory settings
74
Door setting change-over point [73] to [72]
75
Acceleration time open
10 - 30 x 0.1 s
20
Factory settings
76
Acceleration time close
10 - 30 x 0.1 s
20
Factory settings
77
Braking time open
10 - 30 x 0.1 s
20
Factory settings
78
Braking time close
10 - 30 x 0.1 s
20
Factory settings
- -
Exit menu
Menu 9 Service menu
menu
Entry
Selection
item
90
Selection of the door maintenance cycle
0
No service interval (default setting)
1
1000 cycles
2
4000 cycles
3
8000 cycles
4
12000 cycles
5
16000 cycles
6
20000 cycles
7
25000 cycles
8
30000 cycles
9
35000 cycles
10
40000 cycles
11
45000 cycles
12
50000 cycles
91
Cycle counter output door cycles
96
Operating hours counter output – hours
97
Error memory output hours – error code
98
Software version output – serial number – creation
date
99
Reset to default setting