Pre-Installation
ELECTRICAL REQUIREMENTS
WARNING: Electrical Shock Hazard
□ Plug into a grounded 3-prong outlet.
□ Do not remove ground prong.
□ Do not use an adapter.
□ Do not use an extension cord.
□ Failure to follow these instructions can result in death, fire, or electrical shock.
RECOMMENDED GROUNDING METHOD
This air conditioner must be grounded. This air conditioner is equipped with a power supply cord with a three-prong grounding plug. The
cord must be plugged into a three-prong outlet, grounded in accordance with all local codes and ordinances. If a grounded outlet is not
available, it is the customer's responsibility to have a properly grounded three-prong outlet installed by a qualified electrical installer.
It is the customer's responsibility:
□ To contact a qualified electrical installer.
□ To assure that the electrical installation is adequate and conforms to the Nation Electrical Code, ANSI/NFPA 70-last edition, and all local
codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Ma 02169-7471
www.nfpa.org
WIRING REQUIREMENT
Power supply
115V
103.5V min.
126.5 V max.
Model
8K BTU cooling only
10K BTU cooling only
12K BTU cooling only
14K BTU cooling only
4
Time-delay fuse (or circuit breaker)
13A
15A