• The tubing or the flexible hose must be
changed within the prescribed intervals
• Turn of the appliance immediately if smell
of any gass is detected and extinguish any
open flame.

ASSEMBLING THE HEATER

The manufacturer is not responsible for any harm or damage if attention is
not paid to the points described above.
The use of this product and the elements required for that purpose is entire-
ly at the end user's own risk.
HEATER LOCATION AND CLEARANCE
Always maintain: (picture 1)
- 120 cm clearance from combustible materials,
- minimum 100 cm top clearance
- minimum 100 cm side clearance
- Heater must only be placed and used on a firm, level and stable under-
ground.
GAS REQUIREMENTS
Use propane, butane or LGP only. See rating label on the appliance.
Maximum size of cylinder suitable for the appliance is Ø 30 cm x (60-65) cm
(high) (*). Inner dimension of stand with supporting
(*) height depends on the size and type of your gas regulator
Gas supply to the appliance from the gas cylinder: The appliance requires
approved gas hose in 140 cm length and a gas regulator (Hose and regulator
not included). The hose and regulator assembly must conform to local stand-
ard codes.
Regulator maximum inlet pressure must not exceed 690 kPa
Regulator outlet pressure to be 28 mbar (2.8 kPa) to 37 mbar (3.7 kPa)
depending on countries.
The installation must conform to local codes, or in the absence of local codes,
to the standard for the storage and handling of liquid petroleum gases.
A dented, rusted or damaged gas cylinder may be hazardous and should be
checked by an authorized dedicated gas specialist,
Never use a gas cylinder with a damaged valve connection.
The gas cylinder must be arranged to provide for vapor withdrawal from the
operating cylinder.
Never twist the flexible tubes and hoses.
Never connect an unregulated gas cylinder to the heater.
Disconnect the gas cylinder when the heater is not use.
Do not connect the gas cylinder directly to the appliance without regulator.
Use only the type of gas and the type of cylinder specified in these instruc-
tions.
LEAK TESTING
Gas connections on the heater are leak tested at the factory prior to ship-
ment. A complete gas tightness check must be performed at the installation
site due to possible mishandling in shipment and/or installation or because of