ASSEMBLING THE HEATER

HEATER LOCATION AND CLEARANCE
Always maintain: (pic.1)
WARNINGS

GAS REQUIREMENTS

Use propane, butane or LGP only. See rating label on the appliance.
4
40
Have any repairs and/or maintenance carried out by a recognized service
engineer only
Make sure that the correct gas is used and that the gas containers are not
exposed to heat or extreme temperature changes. Always store the gas con-
tainers in a cool, dry and dark place.
Always use a suitable and approved low-pressure regulator. In case of any
doubt contact your local dealer.
Turn of the appliance immediately if smell of any gass is detected and extin-
guish any open flame.
The manufacturer is not responsible for any harm or damage if attention is
not paid to the points described above.
The use of this product and the elements required for that purpose is entirely
at the end user's own risk.
- 120 cm clearance from combustible materials,
- minimum 80 cm top clearance
- minimum 65 cm side clearance
- Heater must only be placed and used on a firm, level and stable under-
ground.
Never use the heater while it is raining, the glass tube would break when it
suddenly met water.
Always turn off the heater while there is a rain.
Never splash any liquid to the glass tube when the heater is working.
The glass tube will be extremely hot when it is working, never try to touch it
and keep the children away from the heater.
Always ensure the heater stands firmly, the glass tube may break if the hea-
ter was fell down onto ground.
Never use the heater if the glass tube has any crack.
Maximum size of cylinder suitable for the appliance is Ø 33 cm x 65 cm (high).
The appliance requires approved gas hose in 60 cm length and a gas regula-
tor. The hose and regulator assembly must conform to local standard codes.
Regulator maximum inlet pressure must not exceed 690 kPa.
Regulator outlet pressure to be 28 mbar (2.8 kPa) to 50 mbar (5 kPa) depen-
ding on countries.
The installation must conform to local codes, or in the absence of local codes,
to the standard for the storage and handling of liquid petroleum gases.
A dented, rusted or damaged gas cylinder may be hazardous and should be
checked by an authorized dedicated gas specialist.
Never use a gas cylinder with a damaged valve connection.
The gas cylinder must be arranged to provide for vapor withdrawal from the
operating cylinder.
Never twist the flexible tubes and hoses.