Setting the parameters
☞
The parameters for exposure time and cooling time cannot be set independently of
each other.
11.16 Press and hold the RESET key.
11.17 Additionally press the
• The LED flashes 4 × briefly.
• The fitting switches to Normal Mode.
• The LED flashes twice with a 1s interval.
11.18 Use keys + and – (
Cooling time
Treatment time
☞
By default, the parameter is set to code 6.
• The LED in the sensor of the fitting confirms the entered code
– LED flashes briefly = unit digit
– LED flashes long = tens digit
Example: The LED flashes 2 x long and 1 x short = Code 21 was set. The exposure
time is 3 min. The cooling time is 10 min.
☞
The parameters for safety window and start delay cannot be set independently of
each other.
11.19 Press and hold the RESET key.
11.20 Additionally press the
• The LED flashes 4 × briefly.
• The fitting switches to Normal Mode.
• The LED flashes twice with a 1s interval.
11.21 Use keys + and – (
OFF key within 2s.
) to set the code for the desired pair of parameters.
0
3 min
1
5 min
2
10 min
3
15 min
4
20 min
5
OFF key within 2s.
) to set the code for the desired pair of parameters.
1 min
3 min
6
11
7
12
8
13
9
14
10
15
5 min
10 min
16
21
17
22
18
23
19
24
20
25
19