13. Additional Settings for the Urinal

These additional settings only apply for concealed urinal fittings with mains power operation.
Switching preliminary flushing on/off
The preliminary flushing is switched off at the factory.
13.1 Press and hold the TEST key.
13.2 Press the
• The LED in the sensor of the fitting flashes:
– 4 x short: Preliminary flushing is switched on.
– 2 × long: Preliminary flushing is switched off.
13.3 Exit the adjustment mode.
• Press the TEST key.
or
• Wait 60 seconds.
Switching intermediate flushing on/off
Intermediate flushing is factory-set to ON.
13.4 Press and hold the TEST key.
13.5 Additionally press the
• The LED in the sensor of the fitting flashes:
– 4 x short: Intermediate flushing is switched on.
– 2 × long: Intermediate flushing is switched off.
13.6 Exit the adjustment mode.
• Press the TEST key.
or
• Wait 60 seconds.
Setting the minimum retention time
The minimum dwelling time is factory-set to 7s.
13.7 Press and hold the TEST key.
13.8 Use the + and – (
• The LED in the sensor of the fitting flashes:
– 4 × short for each adjustment by one step (approx. 1s)
– 2 x long when the respective end setting is reached
13.9 Exit the adjustment mode.
• Press the TEST key.
or
• Wait 60 seconds.
22
ON key within 2s.
OFF key within 2s.
) keys to adjust the minimum retention time in individual steps.