Descargar Imprimir esta página

Deca JOB 635 LAB Manual De Instrucciones página 18

Publicidad

Idiomas disponibles

Idiomas disponibles

Welding process: description of controls
O
P
Q
1 Main adjustment knob
2 Welding current adjustment / multifunction knob
3 Welding voltage adjustment / navigation knob
4 Display
O Sd card connector
P Gas test function
Q Wire load function
Browse through Views
Knob "1" allows you to select the parameters present in the
"Welding parameters bar" and to set the desired values.
Press the knob to confi rm your choise.
Knob "3" controls the "Navigation bar". It is used to move
between the various views and also includes some secondary
adjustments. Press the knob to confi rm your choise.
Screenshot: HOME
Screenshot: Synergic MIG welding
N
308
B
Screenshot: manual MIG welding
B
950057-00 01/06/22
4
2
3
1
A
C
D
A
E
G
17
Screenshot: MIG welding parameters
H
Screenshot: MMA welding
B
Screenshot: TIG welding
B
A) Statusbar. Indicates the main adjustments in operation.
B)Measured values of welding current and voltage.
C)Set values of material thickness / welding current / wire
speed. The choice of which value to display is made by
pressing the "2" knob.
D) Correction of welding voltage: greater or lesser
penetration of the arc. (Knob "3").
E) Wire speed on manual welding.
G) Welding voltage on manual welding.
H) Welding parameters bar. (Press knob "1").
I) Navigation bar. (Press knob "3").
M) Welding current on MMA / TIG process. (Knob "2").
N)
Synergic programs reference number
A
I
A
M
A
M

Publicidad