Descargar Imprimir esta página

Master MH-80TBOA-KFA Manual Del Usuario E Instrucciones página 6

Ocultar thumbs Ver también para MH-80TBOA-KFA:

Publicidad

Idiomas disponibles

Idiomas disponibles

Pre-Lighting Instructions:
Charge the Battery
Ensure battery is fully charged for best run time. Follow
battery manufactures instructions for use, charging and
storing. Heater does not charge the battery.
Over Discharge Protection
Heater has a built in battery protection circuit that will
shut the heater off to protect the battery from over
discharging.
CAUTION
LOCAL SERVICE CENTER OR CALL 800-641-6996
FOR MORE INFORMATION
Starting the Heater: (Ignition)
1. Fill the tank with kerosene or other approved
fuel until needle on fuel gauge points to "F".
2. Replace fuel cap and tighten firmly.
3. Connect the heater to power source, either
approved battery or a three prong (grounded)
power source. You must use a three prong
(grounded) extension cord that is at least 6 feet
long and is a minimum of 14 AWG rating.
4. Turn thermostat control knob to desired
temperature setting.
5. Move the power switch to the "On" position. The
power indicator light will illuminate and heater
will ignite.
NOTE: On first ignition or after refueling, you may hear a
grinding sound just before ignition. This is the fuel pump
removing the air from the fuel line. Your heater will start
up within seconds. If it does not start repeat start-up pro-
cedures with fuel gauge reading at least 1/2 tank.
NOTE: Smoking may occur on first ignition.
NOTE: The electrical components of these heaters are
protected by a fuse mounted in the PC board. If the
heater fails to ignite, check this fuse first and replace if
necessary. Also check the power source to be sure the
proper voltage is being provided to the heater.
TIP: If the heater does not ignite; move
switch to "Off" position, check steps 1-3
above and then move switch to "On" position.
© 2021 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
OPERATION (CONT.)
Use only Master
approved batteries
—CONTACT YOUR
Stopping the Heater (Cool Down):
Turn the power switch to the "Off" position. Combustion
will stop and the Cooling Cycle will begin and last
approx. 5 mins. When the Cooling Cycle is complete
the fan will stop running and it will be safe to unplug the
heater or disconnect the battery.
NOTE: Unplugging the heater or disconnecting the bat-
tery before the Cooling Cycle has been completed may
cause overheating, possible damage to the heater and
heat plate.
Restarting the Heater:
1. Wait ten seconds after Cooling Cycle has been
completed.
2. Follow all ignition procedures.
Long Term Storage:
Use an approved siphon to drain fuel through the
fuel cap opening.
IMPORTANT: Never store leftover kerosene or diesel
between seasons, using old fuel can damage heater.
DO NOT disconnect heater from power source before
cooling cycle has been completed.
TIP: If the heater does not ignite, the
thermostat may be set too low. Turn the
control knob to a higher setting until the
heater ignites. If the heater does not ignite; move
switch to "Off" position, check steps 1-5 above
and then move switch to "On" position.
DANGER
DANGER
RISK OF FIRE! REMOVE BATTERY FROM
HEATER WHEN NOT IN USE
6
Kerosene Forced Air Heater User's Manual
RISK OF FIRE! Never
transport heater with
battery attached

Publicidad

loading