Descargar Imprimir esta página

Casselin CLVAC Manual De Instrucciones página 19

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 38
Before connecting the device, check that the power cable is in good condition; if damaged, it must be
replaced by the manufacturer or its technical assistance service or by qualified personnel.
Prevent the power cable from being stretched.
Filling the detergent and rinse aid dispenser circuits.
For the operation of the dispensers, see the "dosers" paragraphs.
For their proper functioning, the liquid suction pipes (outgoing at the rear of the appliance) must be filled. The
continuous actuation of the dispensers necessary for this filling operation is obtained by placing the device
in the situation in which parameters 08 and 09 must be modified respectively (see paragraph 5.2) and
pressing the key
.
The doser remains active as long as the button is pressed.
NOISE
The noise level from the side and front walls is less than 70 dB(A).
DEVICE DESCRIPTION
1) Control panel
2) Plate basket
3) Wash arm
4) Rinse arm
5) Bonnet opening/closing handle
Security devices
HOOD MICRO-SWITCH: it interrupts all the functions of the device when the door is opened and
does not allow starting when the door is
THERMAL PROTECTION FOR ELECTRIC PUMPS: these devices guarantee protection in the event
of short-circuit and overload.
PROTECTION ON THE WATER HEATER RESISTANCE: a failure of the water heater temperature
control causes, for the resistances with a minimum power of 8 kW, the intervention of a safety
thermostat which can be reset when its temperature drops . For resistors with lower power, the safety
function is guaranteed by a thermal fuse integrated in the resistor.
TANK DIGITAL PRESSURE SWITCH: protects the tank resistance and the washing pump against
running dry. If the water level is too low, the wash pump is not activated. If the level drops during the
operating time, the tank filling solenoid valve is activated, stopping the pump and the washing cycle.
• TANK ANALOG PRESSURE SWITCH: it protects the tank resistance against running dry. If
the water level is too low, the resistance of the tank is not activated.
• WATER HEATER LEVEL SENSOR (only for BA version): it protects the heating elements of
the water heater and the rinsing pump against running dry. If the water level is too low, the
rinse pump is not activated. If the level decreases during the operating time, the tank filling
solenoid valve is activated by the tank (break tank).
open.