Monthly Maintenance; Machine Storage; Technical Specifi Cations - Clarke BextSpot Pro Spotter Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

A - ENGLISH

MONTHLY MAINTENANCE

1)
Flush pump & plumbing with an acetic acid (vinegar) solution to
dissolve any chemical buildup. Mixing Instructions:
a)
Premix 8 oz. of an acetic acid solution with 1 gallon of water
and pour into solution tank.
b)
Turn vacuum /pump switch on
c)
Put fl oor tool head over fl oor drain and pull solution trigger for
one (1) minute.
d)
Turn machine off and allow remaining solution to sit in
machine overnight.
e)
The following day, spray out remaining solution and fl ush
system again with 1 gallon of clean water.
2)
Inspect machine for water leaks.
3)
Check machine for loose or missing nuts, screw and bolts and
replace as necessary.

MACHINE STORAGE

1)
Prior to storing the machine, ensure the solution and recovery
tanks are clean and empty of any solution.
2)
Store machine in upright position in a dry area, with the vacuum
hose removed for air circulation.
NOTE: If you are storing the machine in an area which can freeze, be
sure both tanks and the solution plumbing are empty of all water
and dry!
A - 6
INSTRUCTIONS FOR USE
BextSpot Pro - 56091115
TECHNICAL SPECIFICATIONS
Gallon Capacity
1 Gal (3.79Ltr)
Cleaning Path
4" (10.2cm)
Pump
30PSI
Vac Motor
2-Stage
Voltage
110V
Waterlift
85" (215.9cm)
Cable
21.5ft./Safety Yellow
Wheels
8" (203.2 m m)
Vacuum Hose
8.2ft.
Solution Hose
8.5ft.
2/14

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Clarke130sp

Tabla de contenido