Technical specifications:
Granulator housing
Motor
Power
Nom. amperage
Fuse
Rotor
Piping
Transmission
Weight
Weight w/o motor
Surface treatment
Noise level
Installation and fitting:
When pipes are being fitted on the Granulator, a fixing collar with screws should be used so that the pipe
can only be removed with the aid of tools. The pipes and a support plate for the motor can retain the
Granulator.
When pipes and machine are being fitted and dismantled, the motor must be disconnected from the power
supply. This can be done with a safety cutout interlock switch.
Before the motor is energised, a one-metre pipe must be at least provided on each side of the Granulator
for reasons of safety.
Starting and stopping:
The motor should be fitted with a lockable safety cut-out to enable the Granulator to be started and
stopped separately without stopping the unit with which it is connected.
Maintenance:
The manufacturer recommends the bearings and coupling carrier plate being renewed after max. 3200
hours' operation.
It is also recommended to grind the rotor blades and fixed blades on the same occasion.
See under "Replacing spare parts".
Manual_GR140_160123_EN
Cast iron.
0,75kW type M80
3x400V, 50Hz.
1,75A
10 Amp.
Hard-metal blades.
ø160 mm.
Direct coupling
32 kg.
22 kg.
Powder lacquering
60 dB (A)
EN
2