long hose runs;
extreme twisting of hoses;
rough internal diameter of hoses;
a coupling bore diameter smaller than the hose bore;
obstructions in the hoses (like check valves or dirt inside the hose bore).
j)
Thread the hoses onto the pump ports to secure. Secure the hose connections
with hose clips tightened over the port stubs.
CAUTION! Although the appliance has been designed to be safe and has
been provided with adequate safeguards, and despite the use of additional
safety measures, there is still a low, residual risk of accident or injury during its
operation. Caution and common sense are advised when using the product.
3. Rules of use
This product is intended for evacuation of bilge water, and suitable for handling water
or Diesel fuel.
The user is responsible for any damage caused by non-intended use.
3.1. Preparations for operation
POSITIONING THE APPLIANCE
1. Install the pump in a readily accessible location. The bottom part of the pump
can be reoriented on the housing (see Fig. 6).
2. Mind the correct port assignment shown with "IN" for the suction side and
"OUT" for the discharge side.
3. Install the pump as close to the discharge outlet of the hose as possible. The
shorter the discharge hose is, the better the pump's performance is.
INSTALLING THE APPLIANCE:
1. Choose a location to install the pump in.
2. Mark out the hole drilling pattern using the bolt hole locations in the pump
base lugs.
3. Carefully drill out the holes at the marks and use them to secure the pump
base with suitable bolts. The installation substrate can be braced if needed by
using a block of plywood (Fig. 7 item C).
WARNING! Do not penetrate through the hull when drilling the mounting
holes!
4. Prepare two hoses. Slide hose clips over one end of each hose (use one clip to
secure the hose to the pump discharge port and one clip to secure the hose to

Publicidad