Technical Information
WIN#
Read/ Write
120
R/W
121
R/W
122
R/W
123
Reserved to Agilent service
124
125
R/W
126
R/W
130
Reserved to Agilent service
140
R/W
143
R/W
144
R/W
147
R/W
155
R
157
R/W
174
Type
Meaning
N
Rotational frequency setting (Hz)
N
Maximum rotational frequency in Hz
(active only in Stop condition)
L
Set vent valve on/off (on = closed)
N
Valves operating mode
N
Vent valve opening delay
(expressed in 0.2 sec)
L
Vent Valve selection (N.C./N.O.)
N
External Fan Configuration
L
External Fan activation
N
Vent Valve opening (Time expressed
in 0.2 s)
N
Power Limit Applied expressed in W
N
Gas Load Type
Agilent TwisTorr Medium-TMP Rack Controller User Manual
Admitted Values
680 to WIN 121
(default = 825 for X3512-64016,
714 for X3512-64006 )
680 to 825
(default = 825 for X3501-64016,
714 for X3501-64006 )
1 = open
0 = close
(default = 0)
0 = On Command (Serial Command)
1 = Auto Pump Speed
2 = Autotime
(default = 2)
0 to 65535
(corresponding to 0 to 13107 sec)
(default = 15)
0 = N.C.
1 = N.O.
(default = 1)
0 = Always ON
1 = Automatic
2 = Serial
(default = 0)
0 = OFF
1 = ON
(default = 0)
0 to 65535 bit
0 = infinite
min 0.2 s,
Max 13107 s
(default = 0)
0 = heavy gas
(mass >39, i.e. Ar)
1 = light gas
(mass <39, i.e. N2)
(default = 0)