The lift must be fixed to this surface using heavy-duty anchor fixtures as described in the "Anchor Bolt Installation
Procedure" section of the manual.
The said surface must be capable of supporting at least 25 Kg/cm2 and have a strength rating of at least 250 R'bk.
The layer of concrete must be sufficient to ensure effective installation of the anchor bolts, and have a good
structure to a depth of at least 200 mm.
If a surface of this kind is not available, two separate foundation plinths can be constructed. The minimum
characteristics required are:
The floor must be able to withstand a load equal to the sum of the weight of the lift itself and the maximum payload, bearing
in mind the lift support surface area and anchor fixtures used.
The installation procedure foresees the use of the accessory plugs kit (optional), for equivalent models refer to the table
below and / or to the technical sheets of the product used.
Type
Fischer FBN II 16/50
VoRpA VE.7CE16/ 100-220
4.3 INSTALLATION
After unpacking, handle the pillars with the aid of suitable slings.
Anchor bolt installation procedure:
1. Place the two pillars in the installation zone.
2. Straighten the pillars to the vertical position and then position them so that they are properly aligned with the
distance between them (fig. 3).
3. If necessary place shims underneath the bases of the pillars so that they are firmly sup-ported and the pillars are
perfectly vertical.
4. Use a drill bit ø16 to drill holes at least 100 mm deep, and clean the holes thoroughly.
5. 5.Fit the M16 Fischer FBN II 16x50 or equivalent anchor bolts in the holes and then tighten with a torque wrench
set at 100 Nm: first place the thick washer provided with the fixing kit between the anchor bolt washer and the
pillar base plate.
After a few cycles with full load, check that the anchor bolts are still firmly tightened. This check must be repeated
every 3 months.
Operator's manual [EN]
Min depth for
Ø Foro
installation
16
154
mm
16
110
mm
Concrete class 250 R'bk.
Reinforcement Fe B 44 K.
Dimensions 1000x1000 (figure 3).
Depth 600 mm.
Concrete class 250 R'bk.
Reinforcement Fe B 44 K.
Torque
Extraction force
[Nm]
[KN]
100
17.2
100
16,6
65