Before supplying power to the lift, make the following checks:
Check that the power supply voltage and frequency correspond to the values stated on the rating plate.
Check the condition of the conductors and ensure that the earth conductor is present.
Ensure that there is an overcurrent protection device installed upstream of the lift, with a differential safety
breaker.
Connect the appliance's cable to the mains socket, wiring the three phases R,S,T and the earth conductor with
all due care, and in compliance with the regulations in force.
WARNING
The manufacturer declines liability for any damages resulting from failure to follow the above instructions,
which may invalidate the warranty.
WARNING
Any connections to the workshop electrical panel are the customer's responsibility and must be made by
staff qualified in accordance with the relevant legal requirements.
4.5 ELECTRICAL HOOK UP ON THE CONTROL PANEL
4.51 Electrical Terminal
For more information, see paragraph 8.1 Wiring Diagram of the Control Panel
4.52 Electromagnet
Type 1
68
The electromagnet installation
Install the electromagnet as picture.
The electromagnet's adjustment is made
using the screws of the magnet holder.
Loosening the screws, the magnet
support can be moved.
The right position of the magnet is like
the picture with the harpoon hooked (B)
on the safety from the carriage.
The distance between the slider and the
coil must be 16mm (type1) and 18mm
After adjustment, tighten the screws of
the support.
Type 2
B
18 mm