Descargar Imprimir esta página

Mitsubishi Electric MXZ-2C20NA3 Manual De Instalación página 4

Publicidad

Idiomas disponibles

Idiomas disponibles

1 - 5 . I N S T A L L A T I O N D I A G R A M
Open as a rule
More than 19-11/16 in.
(500 mm) if the front
and both sides are open
e n
More than
3-15/16 in.
(100 mm)
Open as a rule
More than 19-11/16 in. (500 mm) if the
back, both sides and top are open
6-21/32
Air inlet
4-13/32 × 13/16
oval holes (Base bolt M8)
2 . O U T D O O R U N I T I N S T A L L A T I O N
2 - 1 . I N S T A L L I N G
• Be sure to fix the unit's legs ith bolts hen installing it.
• Be sure to install the unit firmly to ensure that it does not fall by an earthqua e or a gust.
• Refer to the figure in the belo for concrete foundation.
Make the foundation
deeper.
3
More than 3-15/16 in. (100 mm)
More than 7-7/8 in. (200 mm) if there are
obstacles to both sides
More than 13-25/32 in.
(350 mm)
O u t d o o r u n i t i n s t a l l a t i o n
33-1/16
19-11/16
Air inlet
Air outlet
T H E U N I T
Fix here w ith
M8 bolts.
Make the foundation
w ider.
After the leak test, apply insulat-
ing material tightly so that there
is no gap.
When the piping is to be attached to
a w all containing metals (tin plated)
or metal netting, use a chemically
treated w ooden piece 25/32 in. (20
mm) or thicker betw een the w all
and the piping or w rap 7 to 8 turns
of insulation vinyl tape around
the piping.
To use existing piping, perform
COOL operation for 30 minutes
and pump do n before removing
the old air conditioner. Rema e flare
according to the dimension for new
refrigerant.
Units should be installed by licensed contractor according to
local code requirements.
169
Air inlet
4-10 × 21
oval holes (Base bolt M8)
Unit : inch
P A R T S T O
B E P R O V I D E D A T Y O U R S I T E
(A) Pow er supply cord*
(B) Indoor/outdoor unit connecting w ire*
(C) Extension pipe
(D) Wall hole cover
(E) Piping tape
Extension drain hose (or soft PVC
(F)
hose, 19/32 in. (15 mm) inner
diameter or hard PVC pipe VP16)
(G) Refrigeration oil
(H) Putty
(I) Pipe fixing band
(J) Fixing screw for (I)
(K) Wall hole sleeve
Soft PVC hose, 15 mm inner
(L)
diameter or hard PVC pipe VP16
for drain socket (1)
* N o t e :
Place indoor/outdoor unit connecting w ire (B) and
pow er supply cord (A) at least 3 ft. (1 m) aw ay from
the TV antenna w ire.
The
'ty for (B) to ( ) in the above table is quantity
to be used per indoor unit.
O u t d o o r u n i t i n s t a l l a t i o n
840
500
Air inlet
Air outlet
1
1
1
1
1
1
Little
amount
1
2 to 7
2 to 7
1
1
Unit : mm

Publicidad

loading