11.6) Flow monitor no, and
Here you can indicate whether the unit is equipped with a power switch. If you enter YES, the
device assumes that a power switch is active.
If there is a water flow, the Ph and chlorine dosing pumps can function. When there is a water
flow, the dosing pumps do not work
A flow switch is included in the ZWMX7525 version, but not in the
ZWMX7520-P version.
11.7) Security alarm on or off or info
The alarm function is prepared to ensure the safe operation of this device and the swimming
pool.
Alarm on:
The alarm screen shows the following:
If after resetting the alarm function the values deviate as described above, the alarm will
continue.
Swimming is not allowed in the pool if the "alarm" indicates a deviation
Alarm off:
- pH too high (pH >8.5)
- pH too low (pH<5.5)
- pH setpoint not reached after 200 minutes of dosing
- Redox too low (<100)
- Rx Setpoint not reached make 400 minutes dosage
The alarm function is necessary to warn the
user of abnormal behaviour of the unit and to
prevent a very large dose of a pH liquid from
being dosed or from dosing or generating too
much chlorine.
The alarm message disappears when the middle menu button (reset)
is pressed or after a power failure.