Never use the device in the alarm OFF position during normal use. If you turn off the alarm, the
alarm function described above will not work for 240 minutes.
The alarm OFF mode is only used to check the values of a swimming
pool that deviate significantly. (as at the first start)."
For example, the pH value can be very high and the Rx value very
low when the pool is first put into use. In this case, you need
to use the alarm function "OFF" to check the pH and chlorine.
When the "alarm off" function is used, swimming in the pool is not allowed
12) Install the suction nipple.
Place the pH suction cup in the acid tank and the chlorine suction cup in the chlorine tank.
It is recommended not to lower the suction cup to the bottom of the jug. If something goes
wrong during dosing, the entire container with chlorine or acid is not pumped into the pool.
13) Start the device
Start the installation by turning on the flow of the pump and the dosing unit.
Switch on the pH dosage (via the switch on the bottom of the dosing pump) until the pH value is
between 7.2 and 7.6. If the pH value is less than 7.2: add pH plus manually to the pool water.
Once the pH value is in the range of 7.2 to 7.6, switch on the chlorine dosage.
With the "Prop" dosing method, the acid and chlorine pumps never work simultaneously.
Make sure that the dosing nipples for acid and chlorine do not leak and that acid and chlorine
are dosed effectively.
14) Verifieer
Regularly check the operation of the probes and the settings by measuring the pH value and the
chlorine content using an alternative method (colour measurement). If necessary, adjust the set
values of the system.
Chlorine control via Rx: set the Rx setpoint value
The Rx (redox) is a measure of the chlorine content (oxidizing capacity) of the pool water. The
higher the Rx, the higher the chlorine content.
the Rx is expressed in mV (millivolts), the chlorine content in ppm (parts per million).
The chlorine content in a swimming pool is ideally between 1 and 1.5 ppm.
14