The chlorine pump continues to
dose
Acid pump and chlorine pump
do not pump.
Chlorine or acid pumps do not
absorb liquid
Liquid (acid or chlorine) in the
dosing compartment of the
chlorine or acid pump
A level indicator is connected
that gives the wrong contact
A flow switch is connected and
it indicates that there is no flow
Setpoint not yet reached
Relay on circuit board remains
switched on
A flow switch is connected and
indicates that there is no flow
Level detectors are connected
that have the wrong contact
The vessel is empty or the
suction foot is above the liquid
level
Suction foot is blocked
The hose is leaking
Injection nozzle clogged
Santoprene dosing hose leaks
Disconnect level indicator
Check the flow rate and flow
switch (go to the flow switch
setting: none)
Check the settings and chlorine
content using the color method.
Contact the supplier.
Check the flow rate and flow
switch (go to the flow switch
setting: none)
Disconnect level indicator
Replace the acid or chlorine
tank. Lower the suction foot.
Replacing the suction cup
ZWMX2205-Z
Hose replacement ZWMX2231-Z
Replace the injection sprayer
ZWMX2220-Z
Check if the dosing nipple is
clogged and replace the dosing
tube.
21