Descargar Imprimir esta página

Truper ROEL-30N-2 Manual página 3

Publicidad

Technical Data
Description
Chuck
Voltage
Frequency
Current
Power
Impact Energy
Drilling Capacity
Speed
Work Cycle
Conductors
Insulation
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
WARNING
Power Requirements
WARNING
Tools with double insulation and reinforced insulation eliminate
the need of a grounded power cord with three prongs or a grounded power
connection.
WARNING
When using an extension cable, verify the gauge is enough for
the power that your product needs. A lower gauge cable will cause voltage drop in
the line, resulting in power loss and overheating. The following table shows the
right size to use depending on cable's length and the ampere capability shown in
the tool's nameplate. When in doubt use the next higher gauge.
Ampere
Capacity
from 0 A and up to 10 A
from 10 A and up to 13 A
from 13 A and up to 15 A
from 15 A and up to 20 A
Code
Drill: n
0
50 minutes' work per 20 minutes idle. Maximum 6 hours per day.
H07RN-F 2 x 1.0 mm
Class II
Number of
Conductors
3
* It is safe to use only if the extensions have a built-in artifact for over current protection.
AWG = American Wire Gauge. Reference: NMX-J-195-ANCE
ROEL-30N-2
19256
SDS Plus Rotary Hammer
SDS Plus
220 V~ - 240 V~
50 Hz
3.85 A
1.13 Hp
3 Joules
Concrete: 1" Metal: 1/2" Wood: 1-9/16"
: 0 - 1 100 RPM | Hammer Drill: 0 - 5 100 impact/min
with 221 °F insulation temperature
2
IP Grade
Power cord grips used in this product: Type "Y".
Build quality: Reinforced Insulation
Thermal insulation on motor winding: Class H
Extension gauge
from 5.9' to 49.2' |
18 AWG( * )
16 AWG
14 AWG
8 AWG
IPX0
Authorized Service Center.
higher than 49.2'
16 AWG
14 AWG
12 AWG
6 AWG
ENGLISH
3

Publicidad

loading

Este manual también es adecuado para:

19256