We thank you for having chosen one of our products. FAAC is certain that
from it you will obtain all the performance you require. All our products are
the result of years of experience in the fi eld of automated systems, with
the added advantage of being part of one of the sector's leading groups.
The manual contains two removable booklets: one with all the
images pertaining to installation and the other titled "Instructions
for use" to give to the end user, which also contains the system
maintenance record.
IMPORTANT NOTES FOR THE INSTALLER
• Before beginning installation of the operator, carefully read the entire
manual.
• Keep this manual for future reference.
• Correct operation and the declared technical specifi cations are obtained
only by complying with the instructions contained in this manual and
using FAAC accessories and safety devices.
• If a mechanical clutch device is not available, to guarantee a suitable
level of automated system safety use a control unit featuring an
adjustable electronic clutch.
• Do not use the automated system to lift people or things.
• This automated system has been designed and built for controlling
vehicle access. Avoid any different use.
• The operator must not be used to control emergency exits or gates
installed on emergency lanes (escape routes).
• Do not pass while the automated system is moving
• Whatever is not explicitly provided for in these instructions is to be
considered strictly forbidden.
• All automated system installation, maintenance and adjustment
operations must be carried out by qualifi ed personnel.
1. DESCRIPTION (Fig.1)
Pos
Bar
Mechanical stops
Spring carrying rod
Limit switch
Adjustable cams
Release device
Gearmotor unit
Spring plate
Balance spring
Electronic control unit
Spring adjustment tie-rod
Earth wire fi xing screw
Foundation plate
Tie-rods
Door
Upright
Release key
Encoder
1.1. TECHNICAL SPECIFICATIONS
Model
Power Supply
Absorbed power (W)
Absorbed current (A)
Thermoprotection (°C)
Capacitor (μF)
Max Torque (Nm)
Opening Time (s)
Max bar length (m)
Type and frequency of use at 20°C
Operating ambient temperature (°C)
Operator weight (Kg)
Protection class
Dimensions
Opening time and number of cycles calculated at a temperature of 20°C
and for installations carried out correctly and without decelerations.
617
Description
617
3
4
6
230 V~ 50 Hz
24 V
250
380
1,1
1,7
140
12,5
60
100
150
2,5
4
8
3
5
7
S3 -
S3 - 50%
100%
60%
-20 +55
63
69
IP X4
See fi g. 3 & 4
No accessories can be applied to 617 3 model bars. Articulation
kits cannot be used with bars longer than 4 metres applied to 617 4
models.
Accessories cannot be used with bars longer than 6 metres applied to
617 6 models.
2. ELECTRICAL PREPARATIONS
(standard system) Fig. 2
Pos
Operator (electrical power supply)
TX photocells
RX photocells
Key switch
Flashing lamp
For cable installation, use adequate rigid and/or fl exible tubes.
Always separate the low-voltage accessories connection cables
from the power supply cables. To avoid possible interference, use
separate sheathing.
Provide the power supply line with an omnipolar switch featuring
a contact opening distance equal to or greater than 3 mm. We
recommend using a 6 A magnetothermic switch with omnipolar
switching.
Always install a differential switch with a 0.03 A threshold upstream
from the system.
When preparing the power supply line, always follow national
system regulations and use a double-insulation cable.
Securely connect the power supply cable and the accessories
connection cables in the board terminals area.
3. INSTALLING THE AUTOMATED SYSTEM
3.1. PRELIMINARY CHECKS
To ensure automated system safety as well as its correct operation, before
proceeding with installation, check that the following conditions are met:
• When in motion, the bar must not encounter obstacles or fl ying power
cables.
• The characteristics of the terrain must guarantee suffi cient solidity of
the foundation plinth.
• No tubes or electrical cables should be present in the plinth digging area.
• If the barrier body is exposed to vehicle transit, provide for adequate
protection against accidental impact, when possible.
• Ensure that there is an effi cient earth plate for connecting the upright
profi le.
3.2. WALLING THE FOUNDATION PLATE
1. Assemble the foundation plate as shown in Fig. 5.
2. Set the foundation plinth as shown in Fig. 6.
The plinth dimensions must be suitable for the terrain type and
model installed.
3. Wall the foundation plate as shown in Fig. 6 and provide for one or
more sheaths for cable running.
4. Use a level to ensure that the plate is perfectly horizontal.
5. Wait for the cement to set.
3.3. MECHANICAL INSTALLATION
1. Remove the 4 upper nuts from the foundation plate.
2. Position the upright on the foundation plate, see Fig. 7, and secure it.
424
3. Prepare the operator for manual operation, as described in paragraph 4.
100
3.3.1. R
IGHT OR LEFT INSTALLATION
Depending on installation needs, the automated system can be installed
3,5
on the right or left:
/
Left-hand installation : Left-hand installation is when, with the barrier
/
100
4
Right-hand installation : Right-hand installation is when, with the barrier
5
The automated system is supplied ready for left-hand closing,
63
fi g. 8 ref. "A". If the bar closing direction is the desired one,
go directly to 3.3.2. "Installing the bar".
To change the automated system from left to right (Fig. 8 ref. "B") proceed
as follows:
1. Remove the adjustment tie-rod, fi g. 8 ref.
6
Description
Cable diameters
closed, the bar is on the right side of the upright,
looking at the automated system from inside the
property (door side).
closed, the bar is on the left side of the upright,
looking at the automated system from inside the
property (door side).
.
3x1.5mm
2
2x0.5mm
2
4x0.5mm
2
2x0.5mm
2
2x1.5mm
2
532041 - Rev.B