Fig. 1: AV-EP name plates for multipole connection (above), for fieldbus connec-
tion (below), without display (above), with display (below)
1
Data matrix code
3
Address
5
Production date
7
Device type
9
Pin assignment (M12 plug)
11
Safety sign: Hot surface
13
Series designation
15
Data length (SER)
The name plates shown for AV-EP pressure regulators are examples.
1. Check the part number on the name plate to determine whether the AV-EP
pressure regulator matches your order.
2. If necessary, check that the base plate matches your order using the material
number on the AV-EP base plate. The material number is located on the top of
the base plate (15). It is only visible if the pressure regulator is disassembled.
AV03-EP
Fig. 2: Position of the material number on the AV-EP base plate
3. Please see the catalog sheet or the material short key in the configurator for
your AV-EP pressure regulator configuration.
The material short key for the AV-EP pressure regulator is structured as follows:
AV0X-EP-000-YYY-ZZZ-QQQQ
Table 3: Meaning of the material short key
Placeholder
See
Meaning
Fig. 1
AV0X
(13)
Series
EP
(13)
Function
AVENTICS™ AV-EP | R414007537-BAL-001-AB | English
14
13
12
13
12
2
Manufacturer
4
Material number
6
Serial number
8
Output pressure range
10
CE mark
12
Internal plant ID
14
LED designations
AV05-EP
15
Abbreviation
AV03 = AV03 series
AV05 = AV05 series
EP = electropneumatic pressure reg-
ulator
Placeholder
See
Fig. 1
11
000
(8)
YYY
(8)
ZZZ
(9, 15)
10
1)
QQQQ
(7)
9
11
10
1)
Example : CL1P: C = Classic, L = LED, 1 = pressure in the operating line is main-
tained briefly, P = actual working pressure value
9
5.2 AV-EP pressure regulator versions
5.2.1 AV-EP pressure regulators for fieldbus connection
AV-EP pressure regulators for fieldbus connection use the AES bus coupler to
communicate within the valve system.
AV03-EP
16
18
Fig. 3: AV-EP pressure regulators for fieldbus connection with display (16, 17) and
without display (18, 19)
5.2.2 AV-EP pressure regulators for multipole connection
AV-EP pressure regulators for multipole connection are actuated via a 5-pin, A-
coded M12 connection.
Meaning
Abbreviation
Min. output pressure
000 = 0 bar
Max. output pressure
060 = 6 bar
100 = 10 bar
Set point
010 = 0–10 V
420 = 4–20 mA
SER = control via fieldbus
Version
C = Classic
S = Smart
Display
L = LED
D = display with integrated LEDs
Defined failure response
0 = operating line is exhausted via
to a lack of UA power sup-
the AV-EP
ply to the valves
1 = pressure in the operating line is
maintained briefly
Output signal
P = actual working pressure value
S = switch output
(only with multipole valve systems)
C = 10 V constant
(only with multipole valve system)
AV05-EP
17
19
24