13.7 Connecting the AV-EP electrical components
The circuit boards in the base plates establish the electrical connection to the bus
coupler.
The components in the valve system are re-arranged after conversion. The bus
coupler reports the new sequence to the control. You must therefore reconfigure
the PLC. The process depends on the fieldbus protocol.
Update your system's PLC configuration. Note the system description on the
u
bus coupler used (on CD R412018133). There, you can find more information
on the PLC configuration key.
For information on electromagnetic compatibility (EMC), see the tech-
nical data
g 16. Key technical
14 Disposal
Comply with national regulations regarding disposal.
u
15 Troubleshooting
The table below contains an overview of malfunctions, possible causes, and
remedies.
If you cannot remedy a malfunction, please contact AVENTICS GmbH.
The address is printed on the back cover of these instructions.
Table 14: Table of malfunctions
Malfunction
Possible cause
No output pressure present
No power supply
No set point stipulated
No supply pressure available Connect the supply pressure
Output pressure too low (less
Supply pressure too low
than the set point)
A consumer with a high air
consumption is located in the
AV-EP operating line and re-
sults in a large pressure drop
in the device.
Air is audibly escaping
Seal is missing or damaged
Pressure regulator is not leak-
tight
Pressure regulator emits
Device with current input is
short pressure pulses
operated with voltage set
point
Output pressure jumps to the
Set point too high
level of the supply pressure
(> 20 mA or > 10 V)
Output pressure too high
Dynamic pressure in exhaust Insert additional exhaust mod-
Flow rate of the switching
Overall air consumption of
valves in the pressure zone is
the switching valves in the
too low
pressure zone is higher than
the max. flow of the AV-EP
Single pressure control flow
Overall air consumption in
rate is too low
the valve system is too high
DIAG LED illuminated red
Parameter error
DIAG LED illuminated red
Safety cutout active
AVENTICS™ AV-EP | R414007537-BAL-001-AB | English
data.
Remedy
Connect power supply
Check power supply polariza-
tion
Switch on system component
Stipulate a set point
Increase supply pressure
Insert an additional pneumatic
supply module
Reduce air consumption
Check the seals and replace, if
necessary
Exchange the pressure regula-
tor
Stipulate the correct type of
set point
Stipulate the correct set point
ule.
Switch fewer valves at once
Insert an additional pneumatic
supply module
Stipulate valid parameteriza-
tion
Exchange device since a pres-
sure sensor is defective.
16 Key technical data
Table 15: General data
General data
Dimensions of AV-EP
including base plate
(width x height x depth)
Weight
Operating temperature range
Storage temperature range
Ambient operating conditions
Version
Permissible medium
Pneumatic connections on the base plate for
single pressure control
Max. particle size
Oil content of compressed air
The pressure dew point must be at least 15 °C below the ambient and medium tempera-
tures and must not exceed 3 °C.
The oil content of compressed air must remain constant during the service life.
u Use only the approved oils from AVENTICS, see the AVENTICS online catalog, chapter
"Technical information".
Mounting orientation
Protection class according to EN 60529/
IEC60529
Relative humidity
Degree of contamination
Use
Table 16: Pneumatic data
Pneumatics
Flow rate values of the AV03-EP single pressure control
pv [bar]
p1 [bar]
11
10
11
10
7
6
7
6
AV03-EP
for fieldbus connection without display
50 mm x 52 mm x
82 mm/91.1 mm*/95.1 mm**
for fieldbus connection with display
50 mm x 72 mm x
82 mm/91.1 mm*/95.1 mm**
All other variants:
50 mm x 72 mm x 100 mm
AV05-EP
for fieldbus connection without display
50 mm x 59 mm x
102 mm/111.1 mm*/115.1 mm**
All other variants:
50 mm x 77 mm x
102 mm/111.1 mm*/115.1 mm**
* Depth with pneumatic plug connectors Ø6
** Depth with pneumatic plug connectors
Ø8
AV03-EP with base plate: 260 ... 335 g
AV05-EP with base plate: 330 ... 405 g
Depending on the configuration, see the on-
line catalog
-10 °C ... 60 °C
–25 °C ... 80 °C
Max. height above sea level: 2000 m
Externally piloted pressure regulator
Compressed air
AV03-EP: Ø 6, Ø 8
AV05-EP: Ø 6, Ø 8
40 µm
3
0–5 mg/m
Any if used with dry and oil-free compressed
air
IP65 (only when assembled and with all plugs
connected)
95 %, non condensing
2
Only in closed rooms
p2 [bar]
Q [l/min]
9.8
350
9
750
5.8
284
5
595
35