1. SPECIFICATIONS
1.1 Technical specifications
Parameter
Minimum - Maximum draught
Fuel consumption
Smoke mass flow rate
Efficiency
Nominal output
Power range
Average CO concentration at 13% of O2
NOx concentration at 13% of O2
OGC concentration at 13% of O2
Particle concentration at 13% of O2
Medium draft (trial)
Net weight
Maximum authorized load (fuel)
Reload height
Logs length
Minimum flue height
Ø Flue duct
Ø Air inlet
Outer fireplace safety distances
Outer fireplace safety distances
Outer fireplace safety distances
Outer fireplace safety distances
Cableado eléctrico de conexión
Flujo aire turbinas (unidad)
Potencia turbinas (unidad)
Distancia seguridad mín. a las salidas de aire
Temperatura media de humos
Tipo de combustión
Conducto
Combustible
Humedad leños combustible
Año Certificación
Nº de Certificado
1.2 Breakdown of delivery components
(Make sure you have all the components described below in relation to the picture on section II of the ANNEXED document)
1.
Fireplace's body.
2.
Heat-resistant spray paint for touch-ups.
3.
Fire grate.
4.
Heat-resistant glove.
5.
Draught limtier
6.
Cleaning cloth
7.
Exterior air inlet kit. (Exterior air inlet connector, connector support, tubular joint, metallic anchor, screws and nuts)
8.
Tool for handling registers and opening door.
9.
Documentation bag: output declaration, energy label, guarantee, technical sheet, and installation and operating
characteristics manual.
10. +T
1.3 Diagram of the equipment's measurements
See the ANNEXED document, section I, page 1.
2. REQUIREMENTS PRIOR TO INSTALLATION
ALL LOCAL STANDARDS, INCLUDING NATIONAL AND EUROPEAN REGULATIONS MUST BE COMPLIED WITH UPON
INSTALLATION OF THE EQUIPMENT.
THE INSTALLATION MUST BE PERFORMED BY A PROFESSIONAL. FAILURE TO COMPLY WITH THIS CLAUSE SHALL
EXONERATE THE MANUFACTURER FROM ANY RESPONSIBILITY.
2.1 Ground. Make sure the ground where the appliance will be placed is able to support the weight of the device. If not, you will need
a load spreading plate for the equitable distribution of the equipment's weight. In case of doubt, please consult a specialist.
2.2 Flue liner. It is mandatory to have a smoke-tight Flue liner going from the connecting point of the base to the outside in observation
of the smoke pipe diameter. The good condition and suitability of this smoke pipe must be certified by a professional and
must also observe the relevant national regulations. This flue liner must be T400 and G type should not be shared with other
(back)
(side)
(glass side)
(frontal)
Model
Habit 76 LD +T | Habit 76 LI +T
11-13 Pa
2,8 kg/h
10,8 g/s
77,3 %
9,4 kW
6,5 – 11 kW
0,08 %
3
104 mg/Nm
3
66 mg/Nm
16,4 mg/Nm
3
11,2 Pa
153,9 kg
4 kg
200 mm
400 mm
4000 mm
180 mm
100 mm
200 mm
200 mm
1000 mm
1000 mm
Silicone hose 3*wire of 1.5 mm
135 m
3
/h
20 W
250 mm
270 ºC
INTERMITENT
NOT SHARED
NATURAL WOOD
12-20 % - two years under cover
2019
1880-CPR-014-19
2
10