6.2.4 Painting. The heatproof paint that covers the inside and outside of the appliance withstands temperatures up to 600 °C and
releases a subtle typical smell that disappears after the first few uses.
It is possible for the paint to jump out in some areas inside the housing after a period of use, due to corrosion caused by liquids,
inadequate fuel types or others not authorized by the manufacturer, etc., In that case it will be necessary to repaint all damaged areas
before a prolonged shutdown period. Use exclusively "Rocal heatproof spray paint".
7. OPTIONAL COMPLEMENTS
Rocal offers various optional items, contact your local dealer to purchase these items. Some of the items are shown below:
Item
ECOntrol
Log store
Ash vaccum cleaner
Bench
Wall support
8. PROBLEMS: CAUSE AND SOLUTION
Below is a table of possible anomalies, their causes and solutions:
PROBLEM
1. Rejects smoke and / or
insufficient draught
2. Excessive dirt on glass
3. Glass bleaching or
colour fading of the plate
4. Poor heating
5. Venting smoke and / or
gases from the front, bad
smell
6. Excessive draft
Code
C7000
E2150-2
ASPIRADOR
E2120-1
CAUSE
Incorrect duct
Lack of air supply for combustion
Incorrect position of registers
Dirty flue duct
Incorrect duct
Inappropriate fuel
Overly closed registers
Excessive temperature caused by excessive
heat in the combustion chamber
Inappropriate fuel
Insufficient load
Combustion control registers in the wrong
position
First lighting
Flammable or combustible items in the
enclosure
or
surrounding
equipment
Crack in the combustion chamber of the
equipment
Incorrect duct
Combustion control registers in the wrong
position
Description
Intelligent combustion control
SOLUTION
Duct servicing*:
-connection
-diameter
-leaks
-insufficient length
-outdoor access
-possible elements blocking the exit
Check vents and / or outside air supply.
Simultaneous operation with other ventilation
devices and / or heating
Setting the register
Contact a professional to clean flue duct. If the
problem persists, contact your dealer.
Revise section on insufficient flue (below).
Use recommended fuel
Adjust registers
Check the fuel load avoiding overheating
Adjust registers
Use recommended fuel
Adding fuel
Adjust register
Wait for the polymerization process of the paint to
finish; this can take from one to several lightings.
Review of insulating materials such as fiberglass,
walls
of
the
fireproof wood or any inflammable elements and
replace them.
Check for tightness and if you discover a crack,
please contact your dealer.
Duct servicing
- Excessive length
- Check Depression
- Incorrect diameter
- Check door gasket
13