NOTE: Setting the reverse gear can not be done when the door is moving.
In doing so, the setting will not be memorized.
PHOTOCELL
When you enable the photocell option, if an object cuts the beam of light
emitted by this device when the door is closing, it will stop and immediately
open completely.
The connection of the photocell needs to be made as explained below:
-
The photocell's supply will be connected to "+24" and "GND".
-
The photocell's signal will be connected to "PBI" and "GND"
Change NO / NC safety
-Keep pressed the "+" button, if it blinks the security is NO, if it blinks twice the security
is NC.
TURNING OFF THE LIGHT
While the door is in motion, the light will be on. The light will remain on for
3 minutes after the end of each maneuver.
AUTOMATIC CLOSING
To activate automatic closing
1-press the "-" button until the led starts to flash, for each flash there is one second of
automatic closing.
2-press again when we want to end the automatic closing time.
To deactivate automatic closing
Press the "-" button until it starts flashing, press it again before it flashes 5 times.
MAINTENANCE AND REPAIRING
- Manual operation of the door. If the door is not properly balanced
and adjusted, please call a qualified technician.
- Make sure the door closes and opens completely. Make the
adjustments if necessary.