- Lubricate the bearings, supports and hinges. The engine does not
need any other lubrication.
TECHNICAL PARAMETERS
Voltage: 230v 50Hz
Frequency: 433-868 MHz
Rolling Code
Use only in dry environments
TROUBLESHOOTING
PROBLEM
The door does not
respond, the LED is off
While the door is
opening or closing, it
stops in full maneuver
and changes its
meaning. The LED
flashes quickly
The door does not
lower and can not be
closed
The door does not
open or close
completely
The wall button works
but the remote
control does not work
The range of control
has been reduced, the
PASSAGE
Motor: DC 24V
Maximum speed: 100 mm/s
Max. use intensity: 4 minutes
Force in stand-by: <5W
CAUSE
Disconnection of the
light motor
The opening / closing
force is higher than
the system
1. The contact of the
photocell is opened by
the presence of an
obstacle
2. The photocell is
activated, but not
connected
The programming is
not correct
1. The remote is not
recorded
2. The remote has no
battery
The control battery is
running out
SOLUTION
Check if the motor is
correctly connected
1. Check the door
balancing system
2. Look at the setting
of the reversing force
1. Remove the
obstacle
2. Disable the
photocell or connect it
Redo the travel
schedule
Save the command
following the
instructions
Replace the control
battery

Publicidad