Descargar Imprimir esta página

TTulpe C-Meister 11 P37 Eco Manual De Instalación, Operación Y Mantenimiento página 10

Publicidad

Idiomas disponibles

Idiomas disponibles

Anomalies and display views
Should the appliance shut down the display shows the letters
Two types of shutdown are possible:
Temporary shutdown (non-permanent). The fault code flashes, shutdown is automatically removed upon resolution of the problem that caused
it. If the fault persists, shutdown switches from temporary to permanent
Permanent shutdown (lock), the fault code is steady. In this case the appliance does not start again automatically and must only be released by
the user or by the operator via the release procedure.
Below are listed the types of alarms, their typical display views and the solutions to reset the appliance:
Display
Flame control module shutdown alarm
Flame control electronic fault alarm
Permanent shutdown
Limit thermostat alarm
Permanent shutdown
Domestic water NTC fault alarm IN-OUT
Permanent shutdown
Parasitic flame alarm
Temporary shutdown
Interrupted modulator cable alarm
Permanent shutdown
Alarm in case of 5 consecutive resets
Permanent shutdown
Low Voltage Alarm
Temporary shutdown
Incorrect mains frequency detection alarm
Temporary shutdown
Flame loss for more than 3 consecutive times
alarm
Permanent shutdown
Button alarm
Temporary shutdown
Alarm comunication remote controller (op-
tional)
Permanent shutdown
Fualt due to gas valve time out
Permanent shutdown
followed by an fault code which should be consulted in relation to the shutdown.
Alarm type
10
Solutions
Press and hold the reset button
pear on the display, release the button.
The appliance automatically restarts. If the fault persists, request the
assistance of a qualified technician.
Press and hold the reset button
on the display, release the button.
The appliance automatically restarts. If the fault persists, request the
assistance of a qualified technician.
Request the assistance of a qualified technician.
Request the assistance of a qualified technician.
Press and hold the reset button
on the display, release the button.
The appliance automatically restarts. If the fault persists, request the
assistance of a qualified technician.
To reset the appliance, disconnect and reconnect the electrical voltage.
Press and hold the reset button
on the display, release the button.
If the fault persists, request the assistance of a qualified technician.
Wait until automatic reset of the water heater.
If the fault persists, request the assistance of a qualified technician.
Wait until automatic reset of the water heater.
If the fault persists, request the assistance of a qualified technician.
Request the assistance of a qualified technician.
This is displayed when you keep pressed the button for more than 30
seconds, once the button is released the fault disappears.
Request the assistance of a qualified technician.
Press and hold the reset button
on the display, release the button.
The appliance automatically restarts. If the fault persists, request the
assistance of a qualified technician.
. As soon as the letters
. As soon as the letters
appear
. As soon as the letters
appear
. As soon as the letters
appear
. As soon as the letters
appear
ap-

Publicidad

loading

Productos relacionados para TTulpe C-Meister 11 P37 Eco

Este manual también es adecuado para:

C-meister 14 p37 eco