•
Monitor the ammeter during the operation. The
maximum amperage for each motor type is as
follows:
a) For motor type 3x400V, 50 Hz: 19.6 A.
b) For motor type 3x480V, 60 Hz: 16.6 A.
•
To make it easier to move straight, fold down the
direction pointer.
Note:
The direction pointer can be adjusted
laterally.
Introduction
WARNING:
maintenance, you must read and
understand the safety chapter.
For all servicing and repair work on the product, special
training is necessary. We guarantee the availability of
professional repairs and servicing. If your dealer is not
14
Maintenance
Before you do
To stop the product
1. Pull the lift lever up.
2. Turn the depth adjustment wheel until the tool drum
does not touch the ground.
3. Push the OFF button for the drive motor and the
OFF button for the drum motor.
4. Wait until all moving parts are fully stopped.
5. Stop the dust extractor.
6. Disconnect the power plug.
a service agent, speak to them for information about the
nearest service agent.
For more detailed information, refer to
www.husqvarna.com.
Maintenance schedule
* = General maintenance done by the operator. The
instructions are not given in this operator's manual.
X = The instructions are given in this operator's manual.
0mm
10
20
30
1838 - 003 - 09.02.2023