Note:
If your product requires an electrical
specification that is not in the table, speak to a
Husqvarna service agent for more information.
Extension cables
Cable length
Calculated at a pre-fuse GG
> 20m
20m > 50m
50m > 75m
Noise and vibration declaration
statement
These declared values were obtained by laboratory
type testing in accordance with the stated directive or
standards and are suitable for comparison with the
declared values of other products tested in accordance
with the same directive or standards. These declared
Product dimensions
A
Length, mm/in.
B
Width, mm/in.
C
Height, mm/in.
4
The cross sections must be re-calculated when other type or dimension pre-fuse are used than is given.
1838 - 003 - 09.02.2023
4
:
A
1410/55.5
750/29.5
1158/45.6
Cross section
≤ 16 A
≤ 32 A
16 amp
32 amp
2
1.5 mm
2.5 mm
2
2
2.5 mm
4 mm
2
2
4 mm
6 mm
values are not suitable for use in risk assessments
and values measured in individual work places may
be higher. The actual exposure values and risk of
harm experienced by an individual user are unique and
depend upon the way the user works, in what material
the product is used, as well as upon the exposure time
and the physical condition of the user, and the condition
of the product.
≤ 63 A
63 amp
2
2
10 mm
2
10 mm
2
16 mm
B
≤ 125 A
125 amp
2
25 mm
2
25 mm
2
35 mm
C
21