2.
ELECTRICAL CONNECTIONS
IMPORTANT: During installation, maintenance and cleaning, the appliance must not be powered.
The appliance must be powered only with 230 Vac voltage.
The radiator is supplied with a three-wire power cable as per the table below:
Brown
Grey or Blue
Black
The power cable must be absolutely connected to power supply through a junction box positioned at 25 cm from the floor and without
using any power plug.
WARNING: The Pilot Wire is intended for radiators sold in France.
If the black "pilot wire" is not used, safety standards impose to insulate it and not to
connect it for any reason to the ground wire.
A disconnection device must be provided on the power mains in accordance with the installation rules.
It is compulsory that the power supply circuit of the appliance is protected by a high sensitivity differential protection device.
Do not insert metal objects in the plastic casing of the adjustment electrical system (right side) and do not use such objects to try to
penetrate it.
If the power cable is damaged, it must be replaced only by a qualified electrician.
2.1 DETAILS ON INSTALLATION CONCERNING THE BATHROOM
Installation must be compliant with the electrical standards and laws in force in Italy.
The radiator is in class II and with IP24 electrical protection.
In the bathroom, it can be installed in areas 2 and 3 (see figure no.1) only if the control device cannot be touched by people that are
using the shower or the bath.
The radiator must not be connected to the ground wire.
In the bathroom, protect the power line with a high sensitivity 30 mA differential protection device.
Install a multipolar switching device. The minimum separation distance between contacts shall be at least 3
mm
18-EN
Phase
Neutral
Pilot Wire
Fig.1