Descargar Imprimir esta página

Amsta AMCG90BM Manual De Instrucciones página 35

Publicidad

Idiomas disponibles

Idiomas disponibles

Gas connection
Any work on the gas equipment and systems should be performed by the
authorized and competent persons.
Prior to installation, check that the local supply conditions (gas type and gas
pressure) are compliant with the product settings.
LPG connection
Be careful that the gas hose and gas valve you use for your oven should be safe. Attach
the gas supply hose at the hose end being the oven and tighten by means of clips and
screw (Figure 4). Make sure it is tightened.
Gas hose of the oven should be me longer than 1500mm.
Pressure of the valve to be used for LPG should be 30 mbar- 300mmSS and certificated.
Do not use an adjustable pressure reducing valve.
Gas supply hose should not pass through the hot section behind the oven.
Temperature of the gas hose should not exceed 90°C (degrees).
Prior to use, make sure the system is gastight.
(Figure 4)
NG (natural gas) connection
If your equipment is set for natural gas, you should have it connected by an installer
registered with the natural gas distribution company. Natural gas connection of your
equipment is 1/2".
If you desire to convert your equipment from LPG to natural gas or from natural gas to
LPG, please call the nearest service center for gas conversion settings.
1-
G1/2 nipple (union)
2-
Silicone gasket
3-
G1/2 Hose inlet (gas inlet)
4-
Metal clamp
5-
Gas hose (inner diameter 8mm)
1-
G1/2 nipple (union)
2-
Silicone gasket
3-
G1/2 NG hose ( natural gas hose as per EN
)
14800
13

Publicidad

loading